  Á¦Ç°¸í : Ultrasonic Flow Sensor
  ¸ðµ¨¸í : UFT75040 Series
  Á¦Á¶¾÷ü : ¿ïÆıâ¼ú
  °¡°Ý : °ßÀû°¡
  °áÀç¹æ¹ý :
  ÃÖ¼ÒÁÖ¹®·® : 1
  ³³±â : ¹ßÁÖÈÄ 30ÀÏÀ̳»
  ¿î¼Û¹æ¹ý : Á÷Á¢¶Ç´ÂÅùè
  ¹ÝÇ°¿©ºÎ : ºÒ°¡
  ´ã´çºÎ¼­ / ´ã´çÀÚ : ¿µ¾÷ºÎ / ±è´ö±ÙºÎÀå
  ¿¬¶ôó : 02-806-4401           
       
 
       
 
 
UFT 75040 Series is an ultrasonic flow meter designed to
address shortcomings of the existing fluid flow sensors.
It adopts the same standard as the existing pipes, so it can
be applied and installed for a wide range of DN15~
DN1000m/m pipes.
¡Ü Can select measurement accuracy : ¡¾1%, ¡¾2%, ¡¾3%
¡Ü Measurement of low flow rates and minimum flow velocity
of 0.01m/s
¡Ü No pressure loss and a zero fault rate with no running parts
¡Ü IP68-rated protection, and used 2 meter deep water.
¡Ü High-temperature erosion-resistant ceramic sensors, and
operating temperature ranging from -40 to 160¡É
¡Ü Can select the vertical or horizontal view and the remote
type.
Accuracy
¡¾1%, ¡¾2%, ¡¾3% of Full scale

Repeatability
<¡¾0.5%

Measurement Cycle
Factory shipping hour 3 Seconds (1~31 Seconds Selection)

Measurement Principle
Ultrasonic time differential method measures flow velocity
depending on properties of changes occurring in ultrasonic
radio wave speeds.

Operation
Measuring Fluid
Water and other water

Input Power Supply
DC24V, 50mA

Application Temperature
Ambient .. - 40¢µ to 176¢µ (-40¡É to +80¡É)
Fluid ....... - 40¢µ to 320¢µ (-40¡É to +160¡É)

Fluid Pressure
10 bar Max.

Sensor Type
High-temperature erosion-resistant ceramic sensor (ultrasonic)

Input Supply Rating
Nomal Flow of Supply Pipe size

Pipe
All-in-one die casting pipes (with water pipe standard)
and selection from DN15 to DN1000 standard range.

Process Connection
Ç¥ÂüÁ¶

Enclosure
IP 68 - Rated Protection
 
 
Home Á¦Ç° ¹× °³¹ß¹®ÀÇ ¿µ¹®»çÀÌÆ®
ÁÖ¼Ò: °æ±âµµ ±¤¸í½Ã ÇϾÈ3µ¿ 201 ±¤¸í½Ã¹ü°ø´Ü 344È£  
ÀüÈ­¹øÈ£: 02-806-4401(ÓÛ), Æѽº¹øÈ£: 02-806-4414, À̸ÞÀÏ: ymkim@ulfatech.co.kr _